• DocumentCode
    811035
  • Title

    The Beam Diagnostics System, Serving the Serpukhov Fast Ejection

  • Author

    Cuperus, J. ; Fabiani, F. ; Kamber, I. ; Nuttall, J.

  • Author_Institution
    CERN, Geneva, Switzerland Now at Lawrence Berkeley Laboratory
  • Volume
    20
  • Issue
    3
  • fYear
    1973
  • fDate
    6/1/1973 12:00:00 AM
  • Firstpage
    523
  • Lastpage
    527
  • Abstract
    A set of beam transformers measures the intensity of each bunch, circulating or ejected. Five electrostatic pick-ups measure the radial position of one selected bunch. Secondary emission grids and luminescent screens give the profile and position of the beam at relevant points. Gated radiation detectors monitor beam loss in the ejection area. All signals are digitalized and fed to a minicomputer on line. Readout is via nixies, CRT analogue displays, pen recorders and a teletype. Statistics can be made over a chosen number of acceleration cycles.
  • Keywords
    Cathode ray tubes; Displays; Electrostatic measurements; Microcomputers; Position measurement; Radiation detectors; Radiation monitoring; Statistics; Teleprinting; Transformers;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1973.4327167
  • Filename