• DocumentCode
    815614
  • Title

    High-efficiency fuel-cell power inverter with soft-switching resonant technique

  • Author

    Wai, Rong-Jong ; Duan, Rou-Yong ; Lee, Jeng-Dao ; Liu, Li-Wei

  • Author_Institution
    Dept. of Electr. Eng., Yuan Ze Univ., Chung Li, Taiwan
  • Volume
    20
  • Issue
    2
  • fYear
    2005
  • fDate
    6/1/2005 12:00:00 AM
  • Firstpage
    485
  • Lastpage
    492
  • Abstract
    In order to reduce the capital and overall operating cost of a fuel-cell system, a high-efficiency fuel-cell power inverter with a simple framework is required. The high-order two-inductance two-capacitance (LLCC) resonant technique is adopted in this study to implement a low-frequency 60-Hz sinewave voltage inverter utilized in the proton exchange membrane fuel-cell (PEMFC) system. The methodology for inverting dc voltage into low-frequency ac voltage is usually generated by the pulse-width-modulation (PWM) technique. However, the PWM-type inverter output has high-frequency harmonic components. Although an adequately designed filter could be utilized to overcome this problem, there are still some undesirable effects introduced by the high-frequency switching loss, electromagnetic-interference, harmonic current, and load variation. A novel power inverter via the LLCC resonant technique is designed for inverting dc voltage into 60-Hz ac sinewave voltage in the PEMFC system. This circuit scheme has the merits of low harmonic components, soft switching, high efficiency, and simplified implementation. The effectiveness of the proposed resonant inverter used for the PEMFC system is verified by numerical simulations and experimental results.
  • Keywords
    PWM invertors; electromagnetic interference; power harmonic filters; proton exchange membrane fuel cells; resonant invertors; switching convertors; 60 Hz; PWM type inverter; electromagnetic interference; filter design; harmonic current; high-efficiency fuel cell power inverter; numerical simulations; proton exchange membrane fuel cell system; pulse width modulation; sinewave voltage inverter; soft-switching resonant inverter; switching loss; AC generators; Biomembranes; Costs; Power harmonic filters; Protons; Pulse width modulation; Pulse width modulation inverters; Resonance; Resonant inverters; Voltage; Fuel cell; proton exchange membrane; pulse-width-modulation technique; resonant inverter; soft switching;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2004.832092
  • Filename
    1432865