DocumentCode
818089
Title
Dosimetry considerations for the high-energy photon/electron environment of HERMES III: implications for experiments and modeling
Author
Beutler, D.E. ; Halbleib, John A. ; Sanford, Thomas W L ; Fehl, D.L. ; Knott, D.P.
Author_Institution
Sandia Nat. Lab., Albuquerque, NM, USA
Volume
38
Issue
6
fYear
1991
fDate
12/1/1991 12:00:00 AM
Firstpage
1736
Lastpage
1745
Abstract
Measurements of energy deposition as a function of equilibrator thickness and position in the HERMES III radiation field are compared to ITS code predictions. These measurements demonstrate the combined photon/electron nature of the radiation field and the importance of the electron field in both measurements and calculations
Keywords
X-ray effects; electron accelerators; electron beam effects; linear accelerators; HERMES III radiation field; dosimetry; electron field; energy deposition; equilibrator; Acceleration; Dosimetry; Electromagnetic scattering; Electron beams; Energy measurement; Magnetic field measurement; Packaging; Particle scattering; Predictive models; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.124170
Filename
124170
Link To Document