• DocumentCode
    818804
  • Title

    Beam Position Measurement System at the Fermilab Main Accelerator

  • Author

    Kerns, Q. A.

  • Author_Institution
    Fermi National Accelerator Laboratory P. O. Box 500 Batavia, Illinois 60510
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1513
  • Lastpage
    1516
  • Abstract
    The beam position system of the Fermilab Main Ring contains one horizontal and one vertical Electrostatic Beam Pickup in each of the 96 cells of the machine. A pair of 75 ohm cables transmits the induced signal from the machine tunnel to the nearest service building. In each of the 24 service buildings, there is a solid-state multiplexer and a beam position detector which processes the A-B signal pairs to produce an intensity-normalized voltage proportional to beam displacement. This voltage is digitized, read into buffer of the Lockheed MAC A, and in turn transferred to the Xerox 530. Horizontal or vertical orbits can be obtained ih 50 millisec. Orbits are obtained at injection, and at a Main Ring Sample time, if requested, anywhere on the acceleration cycle. Injection orbits can be flattened automatically by a program that sets dipole trim magnets.
  • Keywords
    Acceleration; Cables; Electrostatics; Multiplexing; Orbits; Particle beams; Position measurement; Signal processing; Solid state circuits; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327922
  • Filename
    4327922