• DocumentCode
    819194
  • Title

    Modification of the Argonne FN Tandem

  • Author

    Yntema, J.L. ; Billquist, P.

  • Author_Institution
    Argonne National Laboratory, Argonne, Illinois 60439
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1659
  • Lastpage
    1661
  • Abstract
    The Argonne FN tandem now uses Pelletron chains for its charging system and a closed corona system for the voltage distribution along the column. This change has improved the stability of machine operation significantly. The maximum voltage on the terminal is now 9.8 MV compared to 8.6 MV attainable previously in normal operation. The voltage fluctuations in the terminal have decreased by an order of magnitude.