DocumentCode
819824
Title
Performance comparison of unshielded and shielded MR read heads for digital tape recording
Author
Dovek, M.M. ; Seagle, D.J. ; Beaulieu, T.J. ; Christensen, E.R. ; Fontana, R.E., Jr.
Author_Institution
IBM Corp., San Jose, CA, USA
Volume
28
Issue
5
fYear
1992
fDate
9/1/1992 12:00:00 AM
Firstpage
2301
Lastpage
2303
Abstract
The authors report data comparing a shielded magnetoresistive head (SMR) optimized for metal particle tape readback to an unshielded head (UMR) with an identical element. They identify the signal-to-noise ratio penalty for eliminating the shields as a function of tape velocity and data density. They report on the degree of nonlinear distortion for UMR and SMR heads with and without write equalization. From these experiments the performance of an element optimized specifically for the absence of the shields is predicted. An unshielded sensor can be a satisfactory replacement for an SMR sensor at linear densities up to 2500 fr/mm, provided it is redeveloped for optimum signal amplitude and linearity
Keywords
electric distortion; magnetic heads; magnetic shielding; magnetic tapes; magnetoresistive devices; MR read heads; data density; digital tape recording; linear densities; metal particle tape readback; nonlinear distortion; optimum signal amplitude; shielded magnetoresistive head; signal-to-noise ratio penalty; tape velocity; unshielded head; unshielded sensor; write equalization; Digital recording; Frequency; Magnetic domains; Magnetic flux; Magnetic heads; Magnetic separation; Magnetic shielding; Magnetization; Nonlinear distortion; Soft magnetic materials;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.179475
Filename
179475
Link To Document