DocumentCode
824932
Title
Effects of Ionizing Radiation on a 244 Line by 188 Element Charge Injection Device Imager
Author
Killiany, J.M. ; Baker, W.D.
Author_Institution
Naval Research Laboratory, Washington, D. C. 20375
Volume
23
Issue
6
fYear
1976
Firstpage
1644
Lastpage
1647
Abstract
The total dose effects of gamma radiation on an unhardened 244 line by 188 element charge injection device (CID) imager have been investigated. Key device parameters were monitored and the primary failure mechanisms identified. The operating parameters which are compatible with the largest possible total dose tolerance were determined.
Keywords
Charge coupled devices; Clocks; Electrodes; Failure analysis; Interface states; Ionizing radiation; Potential well; Substrates; Switches; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1976.4328556
Filename
4328556
Link To Document