• DocumentCode
    835796
  • Title

    Rigid and flexible thin-film multielectrode arrays for transmural cardiac recording

  • Author

    Mastrototaro, John J. ; Massoud, Hisham Z. ; Pilkington, TheoC ; Ideker, Raymond E.

  • Author_Institution
    Duke Univ., Durham, NC, USA
  • Volume
    39
  • Issue
    3
  • fYear
    1992
  • fDate
    3/1/1992 12:00:00 AM
  • Firstpage
    271
  • Lastpage
    279
  • Abstract
    Thin-film transmural cardiac multielectric arrays were fabricated using integrated-circuit processing techniques. Improvements over conventional handmade arrays, such as a smaller cross-sectional area, a larger number of recording sites per needle, more accurately controlled size and spacing of the recording sites, smaller bipolar spacings, and higher throughput yield, allow for a higher density of closely spaced bipolar electrodes capable of monitoring complex voltage and gradient fields present during ventricular fibrillation and defibrillation. Both rigid and flexible arrays were fabricated and used in the acquisition of transmural electrical signals. In vitro and in vivo testing of the thin-film transmural cardiac multielectrode arrays indicates that there are no adhesion or delamination problems, and no implantation difficulties, and that unipolar and bipolar recordings during normal sinus rhythm and injury potentials in unipolar recordings are similar to those obtained using the handmade electrodes.
  • Keywords
    biological techniques and instruments; electrocardiography; microelectrodes; adhesion; bipolar recordings; delamination; flexible thin-film multielectrode arrays; handmade electrodes; implantation difficulties; in vitro testing; in vivo testing; injury potentials; integrated-circuit processing techniques; needle; normal sinus rhythm; rigid multielectric arrays; throughput yield; transmural cardiac recording; transmural electrical signals; unipolar recordings; ventricular defibrillation; ventricular fibrillation; Defibrillation; Electrodes; Fibrillation; In vitro; Monitoring; Needles; Size control; Throughput; Transistors; Voltage control; Animals; Biocompatible Materials; Dogs; Electric Conductivity; Electrodes, Implanted; Equipment Design; Gold; Monitoring, Physiologic; Platinum; Reproducibility of Results; Ventricular Fibrillation;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.125012
  • Filename
    125012