• DocumentCode
    836733
  • Title

    Plasma Neutron Diagnostic Techniques with Good Spatial and Energy Resolution

  • Author

    Slaughter, Dennis R.

  • Author_Institution
    Lawrence Livermore Laboratory, University of California, Livermore, California 94550
  • Volume
    26
  • Issue
    1
  • fYear
    1979
  • Firstpage
    802
  • Lastpage
    808
  • Abstract
    A neutron-detection system has been assembled to provide both spatial and energy information from the neutrons produced in advanced fusion experiments. Techniques described are applicable to experiments where the neutron pulse is on the order of one-second duration. The system gives spatial resolution of about 1 cm at distances of 1 to 2 m and energy resolution of 0.6 MeV at 14 MeV. In all cases, pulseshape discrimination is used to distinguish neutrons from gamma rays.
  • Keywords
    Energy resolution; Magnetic confinement; Neutrons; Plasma confinement; Plasma density; Plasma diagnostics; Plasma measurements; Plasma temperature; Pulse measurements; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4329730
  • Filename
    4329730