• DocumentCode
    837370
  • Title

    Beam Quality Improvement at JULIC

  • Author

    Reich, J. ; Brings, R. ; Linz, J. ; Wucherer, P.

  • Author_Institution
    Institut fÿr Kernphysik, Kernforschungsanlage Jÿlich, D-5170 Jÿlich, W. Germany
  • Volume
    26
  • Issue
    2
  • fYear
    1979
  • fDate
    4/1/1979 12:00:00 AM
  • Firstpage
    2007
  • Lastpage
    2011
  • Abstract
    To improve the external beam quality at JULIC, three different measures have been undertaken: the development of a systematic procedure for beam phase optimization, the precise adjustment of the center region to nominal values as well as the installation of harmonic coils near the cyclotron center and the introduction of two axial phase slits according to calculations for proper axial imaging. Starting with a cyclotron as it was tuned in the former day by day operation, the successive application of the above means resulted in an improvement of the radial emittance by a factor of 2 to 10 mm.mrad and of the energy resolution by a factor of 3 to below 1.5.10-3. The three different means for better machine tuning and their effect on the external beam quality are described.
  • Keywords
    Acceleration; Coils; Cyclotrons; Energy resolution; Extraterrestrial measurements; Kinematics; Nuclear physics; Particle beams; Phase measurement; Radio frequency;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4329797
  • Filename
    4329797