• DocumentCode
    839850
  • Title

    FLAG unfurls-modern metering and the IEC/FLAG protocol

  • Author

    Wilczynski, Piotr

  • Author_Institution
    Landis & Gyr Energy Management UK Ltd., Telford, UK
  • Volume
    39
  • Issue
    1
  • fYear
    1993
  • fDate
    1/21/1993 12:00:00 AM
  • Firstpage
    35
  • Lastpage
    37
  • Abstract
    Electricity metering is not what it was. In the past few years, advances in technology have brought dramatic changes; the traditional electromechanical meters, and associated time switches, are being replaced by microprocessor-based meters, with a variety of sensors, used to measure directly or indirectly the amount of energy consumed. These new types of meter are very versatile, supporting such facilities as multirate registers, rate switching and recording maximum demand. Here, the author describes how the IEC/FLAG communications protocol meets the needs of meter programming and automatic data collection
  • Keywords
    computerised instrumentation; microcomputer applications; power measurement; power system measurement; protocols; telemetering; watthour meters; IEC/FLAG protocol; automatic data collection; communications; computerised instrumentation; maximum demand; microprocessors; multirate registers; power system measurement; programming; rate switching; sensors; telemetering; watthour meters;
  • fLanguage
    English
  • Journal_Title
    IEE Review
  • Publisher
    iet
  • ISSN
    0953-5683
  • Type

    jour

  • Filename
    191578