• DocumentCode
    840531
  • Title

    Irreversible Electroporation Attenuates Neointimal Formation After Angioplasty

  • Author

    Maor, Elad ; Ivorra, Antoni ; Leor, Jonathan ; Rubinsky, Boris

  • Author_Institution
    Biophys. Grad. Group, California Univ., Berkeley, CA
  • Volume
    55
  • Issue
    9
  • fYear
    2008
  • Firstpage
    2268
  • Lastpage
    2274
  • Abstract
    Restenosis following coronary angioplasty represents a major clinical problem. Irreversible electroporation (IRE) is a nonthermal, nonpharmacological cell ablation method. IRE utilizes a sequence of electrical pulses that produce permanent damage to tissue within a few seconds. The left carotid arteries of eight rats underwent in vivo intimal damage using two Fogarty angioplasty catheters. The procedure was immediately followed by IRE ablation in four rats, while the remaining four were used as the control group. The IRE ablation was performed using a sequence of ten dc pulses of 3800 V/cm, 100 mus each, at a frequency of ten pulses per second, applied across the blood vessel between two parallel electrodes. The electrical conductance of the treated tissue was measured during the electroporation to provide real-time feedback of the process. Left carotid arteries were excised and fixated after a 28-day follow-up period. Neointimal formation was evaluated histologically. The use of IRE was successful in three out of four animals in a way that is consistent with the measurements of blood vessel electrical properties. The integrity of the endothelial layer was recovered in the IRE-treated animals, compared with control. Successful IRE reduced neointima to media ratio (0.57 plusmn 0.4 versus 1.88 plusmn 1.0, P = 0.02). Conclusions: We report for the first time the in vivo results of attenuation of neointimal formation using IRE. Our study shows that IRE might be able to attenuate neointimal formation after angioplasty damage in a rodent model of restenosis. This approach may open new venues in the treatment of coronary artery restenosis after balloon angioplasty.
  • Keywords
    bioelectric phenomena; biomedical electrodes; blood vessels; cardiovascular system; cellular biophysics; diseases; electrical conductivity; surgery; Fogarty angioplasty catheter; balloon angioplasty; blood vessel electrical property; coronary angioplasty; coronary artery restenosis; electrical conductance; electrical pulse sequence; irreversible electroporation; left carotid artery; neointimal formation; nonpharmacological cell ablation method; real-time feedback; tissue damage; Angioplasty; Animals; Blood vessels; Carotid arteries; Catheters; Electric variables measurement; Electrodes; Frequency; In vivo; Rats; Angioplasty; bioelectric phenomena; biomedical engineering; biophysics; blood vessels; cardiology; electric field effects; electroporation; restenosis; Angioplasty, Transluminal, Percutaneous Coronary; Animals; Catheter Ablation; Coronary Restenosis; Electrochemotherapy; Rats; Rats, Sprague-Dawley; Teratocarcinoma; Treatment Outcome; Tunica Intima;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.923909
  • Filename
    4603157