DocumentCode
845712
Title
An international comparison of power meter calibrations conducted in 1987
Author
Moore, William J M ; So, Eddy ; Oldham, Nile M. ; Miljanic, Etar N. ; Bergeest, Rainer
Author_Institution
Nat. Res. Council of Canada, Ottawa, Ont., Canada
Volume
38
Issue
2
fYear
1989
fDate
4/1/1989 12:00:00 AM
Firstpage
395
Lastpage
401
Abstract
The results of an intercomparison of power meter calibrations conducted during 1987 between the National Research Council of Canada, Ottawa, the US National Bureau of Standards, Gaithersburg, the Physikalisch-Technische Bundesanstalt, Braunschweig, and the Institut Mihailo Pupin, Belgrade, are described. The comparison was implemented by a transfer standard consisting of a time-division multiplier watt-converter developed at the Institut Mihailo Pupin. The measurements were made at 120 V, 5 A, and 50 and 60 Hz, at power factors of 1.0, 0.5 lead and lag, and 0.0 lead and lag. An agreement between the laboratories of better than 20 ppm is obtained
Keywords
calibration; power measurement; 120 V; 1987; 5 A; 50 Hz; 60 Hz; Institut Mihailo Pupin; National Research Council of Canada; Physikalisch-Technische Bundesanstalt; US National Bureau of Standards; international comparison; power meter calibrations; time-division multiplier watt-converter; transfer standard; Calibration; Councils; Instruments; Laboratories; NIST; Power measurement; Reactive power; Standards development; Switches; Voltage;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.192314
Filename
192314