DocumentCode
847846
Title
Influence of the delay of the first corona pulse on the switching impulse breakdown probability
Author
Menemenlis, C. ; Anis, H.
Author_Institution
Hydro-Quebec Institute of Research, Varennes, Quebec, Canada
Volume
94
Issue
2
fYear
1975
fDate
3/1/1975 12:00:00 AM
Firstpage
455
Lastpage
466
Abstract
Tests with a rod-plane gap with a rounded termination of the rod show that the delay of the first corona pulse affects the positive switching impulse breakdown probability. The inverted S form or local inconsistencies of the breakdown probability distribution are connected with particular statistical features of the delay of the first corona pulse. The influence of the rod termination or the impulse front on the breakdown probability distribution is explained in terms of the delay of the first corona pulse.
Keywords
Breakdown voltage; Corona; Delay; Electric breakdown; Electrodes; IEEE members; Impulse testing; Insulation; Probability distribution; Pulse shaping methods;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/T-PAS.1975.31872
Filename
1601474
Link To Document