• DocumentCode
    848008
  • Title

    Multi Needle Counter with Cathode Focusing

  • Author

    Comby, G. ; Mangeot, P.

  • Author_Institution
    Département de Physique des Particules Elémentaires CEN-Saclay, B.P. 2, 91190 Gif-sur-Yvette, France
  • Volume
    27
  • Issue
    1
  • fYear
    1980
  • Firstpage
    106
  • Lastpage
    110
  • Abstract
    A new type of multi needle counter is proposed. The repartition of electric field lines imposed by the electrode geometry drifts electrons efficiently from the whole sensitive volume to the multiplicative zone. The high amplification factor facilitates signal acquisition without disturbing the independence of the cells. This article describes a number of tests showing the ability of the multi needle detector with cathodic focusing to solve imaging problems of simultaneous ionizing events. Several applications are described such as the detection of far ultra violet light.
  • Keywords
    Cathodes; Counting circuits; Detectors; Electrodes; Electrons; Event detection; Focusing; Geometry; Needles; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1980.4330812
  • Filename
    4330812