DocumentCode
851515
Title
Parameter identification and verification of low order boiler models
Author
Herget, Charles J. ; Park, Chan U.
Author_Institution
Iowa State University, Ames, Iowa
Volume
95
Issue
4
fYear
1976
fDate
7/1/1976 12:00:00 AM
Firstpage
1153
Lastpage
1158
Abstract
The results of studies performed for the verification and parameter identification of a low-rder boiler model from actual operating data are presented. The model chosen for identification and verification is a linear fourth order system with eight unknown parameters and two inputs and two outputs. The model is intended for use in stability studies over the time interval of approximately one-half minute to a few minutes following a disturbance.
Keywords
Boilers; Mathematical model; Parameter estimation; Power generation; Power system dynamics; Power system interconnection; Power system modeling; Power system simulation; Power system stability; Testing;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/T-PAS.1976.32208
Filename
1601810
Link To Document