DocumentCode
857123
Title
Large Dynamic Range Beam Profile Measurement in a High Background Environment
Author
Merz, W. ; Dixon, R. ; Harrison, M. ; McCarthy, J.
Author_Institution
Fermi National Accelerator Laboratory Batavia, Illinois 60510 U.S.A.
Volume
28
Issue
3
fYear
1981
fDate
6/1/1981 12:00:00 AM
Firstpage
2372
Lastpage
2374
Abstract
Beam profile measurements using a scanning target and loss monitor in the Fermilab Main Ring extraction channel have long proved their usefulness as a diagnostic method in analyzing extraction problems. To extend these measurements to a sensitivity greater than in the present system a different technique has been employed. A simple three element particle telescope viewing the scanning target allows a sensitive measurement of the tail on the edges of the beam profiles as well as the relative particle densities of the extracted beam and the circulating beam in the Main Ring. Both these regions are of significant interest in understanding extraction losses. The details of the profile measurement technique, some results using the telescope and possible methods of improving the measurements are discussed.
Keywords
Density measurement; Dynamic range; Loss measurement; Measurement techniques; Monitoring; Particle beam measurements; Particle beams; Particle measurements; Tail; Telescopes;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1981.4331696
Filename
4331696
Link To Document