• DocumentCode
    858216
  • Title

    Performance Optimization of a Cusp-Field Ion Source and High-Perveance Extractor

  • Author

    Meyer, E.A. ; Armstrong, D.D. ; Schneider, J.D.

  • Author_Institution
    Los Alamos National Laboratory, Los Alamos, New Mexico 87545
  • Volume
    28
  • Issue
    3
  • fYear
    1981
  • fDate
    6/1/1981 12:00:00 AM
  • Firstpage
    2687
  • Lastpage
    2689
  • Abstract
    The injector for the Fusion Materials Irradiation Test (FMIT) Facility must deliver a 110-mA dc beam of deuterons or H2+ ions to the radio-frequency quadrupole (RFQ) accelerator at 75-keV energy. Operational parameters of a hydrogen-fed cusp-field ion source and a high-perveance extractor have been evaluated on a test stand and on the recently completed first stage of the prototype injector (Fig. 1).
  • Keywords
    Current density; Electrodes; Electron beams; Geometry; Ion accelerators; Ion sources; Magnets; Optimization; Particle beams; Testing;