DocumentCode
870230
Title
Spark-Gap Crowbar for High-Voltage Power Supply
Author
Mitra, A.K. ; Tallerico, P.J.
Author_Institution
AT-5, MS H827 Los Alamos National Laboratory, Los Alamos, NM 87545
Volume
30
Issue
4
fYear
1983
Firstpage
2862
Lastpage
2864
Abstract
A new crowbar circuit employing a pressurized spark gap has been designed to replace the existing ignitron crowbar that protects a 500-kW klystron tube when it arcs. The spark gap offers definite performance advantages when compared to the conventional ignitron circuits. The small overall size makes the spark gap more convenient and the very few components make it more reliable than the ignitron crowbar.
Keywords
Circuit breakers; Circuit testing; Fires; Fuel storage; Klystrons; Optical transmitters; Power supplies; Protection; Spark gaps; Vacuum arcs;