DocumentCode
873414
Title
Some properties of an injection-locked pulsed magnetron in a coherent-echo-detection system
Author
Seavey, M.H.
Author_Institution
US Air Force, Cambridge Research Laboratories, Bedford, USA
Volume
3
Issue
8
fYear
1967
fDate
8/1/1967 12:00:00 AM
Firstpage
375
Lastpage
377
Abstract
An injection-locked pulsed magnetron is studied by observing echo pulses from an acoustic-delay medium. Phase coherence at 9.3GHz is observed for injection ratios as high as 40dB. Long-term stabilities better than one part in 105 per hour are measured. Injection-pulse amplification is observed at frequencies outside the locking band.