• DocumentCode
    881867
  • Title

    Accuracy of Coupled Monte-Carlo/Next-Event-Estimator for Bremsstrahlung Dose Predictions

  • Author

    Pregenzer, Arian L. ; Halbleib, John A.

  • Author_Institution
    Sandia National Laboratories P. O. Box 5800 Division 1231 Albuquerque, NM 87185
  • Volume
    32
  • Issue
    6
  • fYear
    1985
  • Firstpage
    4405
  • Lastpage
    4409
  • Abstract
    The accuracy of an efficient hybrid Monte Carlo/ analytic method for predicting the spatial dependence of x-ray energy deposition in common dosimetry is determined by comparing its predictions with those of full Monte Carlo Transport. For x-ray simulators, the hybrid model underpredicts energy deposition in thermoluminescent dosimetry by failing to account for Compton buildup and overpredicts deposition in gold calorimetry by failing to account for the lack of electron equilibration and fluorescence escape. For gamma simulators, the method accurately predicts the deposition in thermoluminescent dosimetry. We also find that the 2.16-mm Al electron equilibrators used with our standard thermoluminescent dosimeters are excessive for x-ray simulators and insufficient for gamma simulators.
  • Keywords
    Dosimetry; Electron beams; Fluorescence; Gold; Ionization; Laboratories; Monte Carlo methods; Production; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4334132
  • Filename
    4334132