• DocumentCode
    882630
  • Title

    Cavity-Coupling Investigation for the Phermex 50 MHz RF Accelerator

  • Author

    Pogue, E.W. ; Buskirk, F.R.

  • Author_Institution
    Los Alamos National Laboratory P. O. Box 1663 Los Alamos, NM 87545
  • Volume
    32
  • Issue
    5
  • fYear
    1985
  • Firstpage
    2852
  • Lastpage
    2853
  • Abstract
    The PHERMEX accelerator is a three-cavity rf linac that operates at 50 MHz. Each cavity has a radius of 2.3 m and a length of 2.6 m. The accelerator produces an electron beam with a peak current of 500 A and energy of 30 MeV.[1,2] RF power is supplied by multiple 2.5-MW tetrodes feeding coaxial lines with loops in the cavity wall. To increase the fields, multiple tetrodes and coupling loops must be used in each cavity; the problems associated with multiple-loop coupling are investigated.
  • Keywords
    Acceleration; Coaxial components; Coupling circuits; Electron accelerators; Electron beams; Equivalent circuits; Feeds; Impedance; Radio frequency; Radiofrequency amplifiers;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4334203
  • Filename
    4334203