• DocumentCode
    882798
  • Title

    Experimental Study of Long Coupled Helix Resonator

  • Author

    Liang, Z.X. ; Li, W.G. ; Li, K. ; Qian, W.S. ; Han, C.C.

  • Author_Institution
    Department of Technical Physics, Peking University Beijing, China
  • Volume
    32
  • Issue
    5
  • fYear
    1985
  • Firstpage
    2894
  • Lastpage
    2896
  • Abstract
    Experimental tests of a coupled normal temperature low a helix resonator with six-half-wavelength are described. The frequency shift and dynamic instability of the resonator are studied experimentally. The mechanical vibration caused by ponderomotive effect has been controlled. This resonator can run stably at a RF power of 50 KW , frequency of 27 MHz, duty factor of 1/6, and the maximum voltage gain is more than 1.1 MV. Some measures have been taken to increase the stability of the helix. The resonator tested is a model for heavy ion booster following a small van de graff accelerator.
  • Keywords
    Frequency measurement; Gain measurement; Life estimation; Power measurement; Radio frequency; Stability; Temperature; Testing; Vibration control; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1985.4334218
  • Filename
    4334218