DocumentCode
882798
Title
Experimental Study of Long Coupled Helix Resonator
Author
Liang, Z.X. ; Li, W.G. ; Li, K. ; Qian, W.S. ; Han, C.C.
Author_Institution
Department of Technical Physics, Peking University Beijing, China
Volume
32
Issue
5
fYear
1985
Firstpage
2894
Lastpage
2896
Abstract
Experimental tests of a coupled normal temperature low a helix resonator with six-half-wavelength are described. The frequency shift and dynamic instability of the resonator are studied experimentally. The mechanical vibration caused by ponderomotive effect has been controlled. This resonator can run stably at a RF power of 50 KW , frequency of 27 MHz, duty factor of 1/6, and the maximum voltage gain is more than 1.1 MV. Some measures have been taken to increase the stability of the helix. The resonator tested is a model for heavy ion booster following a small van de graff accelerator.
Keywords
Frequency measurement; Gain measurement; Life estimation; Power measurement; Radio frequency; Stability; Temperature; Testing; Vibration control; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4334218
Filename
4334218
Link To Document