• DocumentCode
    891534
  • Title

    Discussion, with reply, on "Assessment of deterioration in epoxy/mica machine insulation" by Y.J. Kim and J.K. Nelson

  • Author

    Danikas, M.G.

  • Volume
    28
  • Issue
    2
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    303
  • Lastpage
    305
  • Abstract
    The commenters raise some questions regarding the measurements reported in the above titled paper (ibid., vol.27, pp.1026-39, October 1992) and their meaning. J.K. Nelson answers some of the questions in terms of the paper´s objectives.<>
  • Keywords
    ageing; composite insulating materials; filled polymers; insulation testing; machine insulation; mica; partial discharges; ageing; deterioration assessment; dynamic stagnation voltage; epoxy/mica machine insulation; high electric stress; partial discharges; Conducting materials; Conductivity; Conductors; Insulation; Partial discharges; Pulse measurements; Shape measurement; Stators; Stress; Voltage;