DocumentCode
903237
Title
Closed Orbit Correction of the NSLS VUV Ring
Author
Bozoki, E. ; Bittner, J. ; Blumberg, L. ; Dickinson, T. ; Galayda, J.
Author_Institution
National Synchrotron Light Source Brookhaven National Laboratory Upton, NY 11973
Volume
30
Issue
4
fYear
1983
Firstpage
3106
Lastpage
3108
Abstract
We describe the results obtained from the orbit correction system in the NSLS VUV storage ring which consists of 24 PUE stations and 16 horizontal and vertical correction dipoles. The data were obtained by the PUEREAL module of the RING control program which provides automatic switching of the signal from individual electrodes of the PUE stations and provides/ a readout at harmonic of the RF frequency. The closed orbit is then calculated and corrected by measured displacements of the PUE´s from the adjacent quadrupoles. The ORBIT module of the RING program was used to minimize the RMS orbit deviations choosing the most effective correctors and calculating their strengths. For the horizontal case, the correction was accomplished using 3 correctors in two iterations starting with RMS values X = 2.9 mm to X = 0.9 mm. Vertically three iterations and 6 correctors were required to correct the RMS value from Z = 6.8 mm to Z = 0.8 mm.
Keywords
Coaxial components; Displacement measurement; Electrodes; Extraterrestrial measurements; Orbital calculations; Radio frequency; Relays; Spectral analysis; Storage rings; Switches;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1983.4336584
Filename
4336584
Link To Document