DocumentCode
904811
Title
Thermal Analysis and Loss in Shunt Impedance of the LEP Accelerating Cell
Author
Wilson, I. ; Henke, H.
Author_Institution
CERN, 1211 Geneva 23, Switzerland
Volume
30
Issue
4
fYear
1983
Firstpage
3590
Lastpage
3592
Abstract
Basic formulae governing thermal flow in water-cooled solids are qiven. By calculating the heat dissipation at room temperature of the LEP accelerating cell with the program SUPERFISH and then using this as input to the thermal analysis program DOT, the surface temperatures and losses at full power have been estimated. Good agreement is obtained when these LEP results are scaled and compared with measurements made on similar accelerating structures in PEP and PETRA. The calculated decrease in shunt impedance of 4.2% with respect to the room temperature value has been stubstantiated by experimental measurements on a prototype LEP cavity.
Keywords
Acceleration; Cooling; Heat transfer; Impedance measurement; Radio frequency; Solids; Surface impedance; Temperature; US Department of Transportation; Water heating;