• DocumentCode
    904811
  • Title

    Thermal Analysis and Loss in Shunt Impedance of the LEP Accelerating Cell

  • Author

    Wilson, I. ; Henke, H.

  • Author_Institution
    CERN, 1211 Geneva 23, Switzerland
  • Volume
    30
  • Issue
    4
  • fYear
    1983
  • Firstpage
    3590
  • Lastpage
    3592
  • Abstract
    Basic formulae governing thermal flow in water-cooled solids are qiven. By calculating the heat dissipation at room temperature of the LEP accelerating cell with the program SUPERFISH and then using this as input to the thermal analysis program DOT, the surface temperatures and losses at full power have been estimated. Good agreement is obtained when these LEP results are scaled and compared with measurements made on similar accelerating structures in PEP and PETRA. The calculated decrease in shunt impedance of 4.2% with respect to the room temperature value has been stubstantiated by experimental measurements on a prototype LEP cavity.
  • Keywords
    Acceleration; Cooling; Heat transfer; Impedance measurement; Radio frequency; Solids; Surface impedance; Temperature; US Department of Transportation; Water heating;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1983.4336735
  • Filename
    4336735