• DocumentCode
    908537
  • Title

    Performance Report for Stanford/SLAC Multi-Channel Sample-and-Hold Device

  • Author

    Haller, G.M. ; Freytag, D.R. ; Walker, J.T. ; Chae, S.I.

  • Author_Institution
    Stanford Linear Accelerator Center Stanford University, Stanford, California, 94305
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    221
  • Lastpage
    225
  • Abstract
    Test results on a newly developed Multi-Channel Sample- And-Hold Calorimeter Data Unit (CDU) are presented. The device is organized as 32 input channels, each consisting of four storage cells to take samples of the 32 analog signals at four separate times. The design goals for the development were wide dynamic range and long hold times. Therefore, each storage cell is laid out in a fully differential way and consists of a sampling stage for the signal and another identical stage for a reference voltage. Results on the performance of the device are described.
  • Keywords
    Buffer storage; Capacitors; Character generation; Clocks; Contracts; Dynamic range; Linear accelerators; Sampling methods; System testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337086
  • Filename
    4337086