DocumentCode
912631
Title
Characteristics of 2-winding capacitor motors with tapped auxiliary windings
Author
Yokozuka, T. ; Miyake, H.
Author_Institution
Gunma University, Department of Electrical Engineering, Faculty of Engineering, Kiryu, Japan
Volume
134
Issue
5
fYear
1987
fDate
9/1/1987 12:00:00 AM
Firstpage
261
Lastpage
268
Abstract
2-winding capacitor motors with tapped auxiliary windings have been widely used in Japan to drive shaft-mounted fans. Principal performance equations are derived by applying the symmetrical components method to an equivalent circuit. The optimum tap position and symmetrical conditions, effects of equivalent circuit parameters on the alternating torque, steady-state torque speed curve, and the efficiency are discussed, based on these equations. The motor is compared with the T- and L-connected tapped winding capacitor motors.
Keywords
capacitor motors; equivalent circuits; machine testing; machine windings; torque; 2-winding capacitor motors; L-connected tapped winding capacitor motors; T-connected tapped winding capacitor motors; alternating torque; efficiency; equivalent circuit parameters; optimum tap position; performance equations; shaft-mounted fans; steady-state torque speed curve; symmetrical components method; tapped auxiliary windings;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings B
Publisher
iet
ISSN
0143-7038
Type
jour
DOI
10.1049/ip-b:19870042
Filename
4644406
Link To Document