• DocumentCode
    912631
  • Title

    Characteristics of 2-winding capacitor motors with tapped auxiliary windings

  • Author

    Yokozuka, T. ; Miyake, H.

  • Author_Institution
    Gunma University, Department of Electrical Engineering, Faculty of Engineering, Kiryu, Japan
  • Volume
    134
  • Issue
    5
  • fYear
    1987
  • fDate
    9/1/1987 12:00:00 AM
  • Firstpage
    261
  • Lastpage
    268
  • Abstract
    2-winding capacitor motors with tapped auxiliary windings have been widely used in Japan to drive shaft-mounted fans. Principal performance equations are derived by applying the symmetrical components method to an equivalent circuit. The optimum tap position and symmetrical conditions, effects of equivalent circuit parameters on the alternating torque, steady-state torque speed curve, and the efficiency are discussed, based on these equations. The motor is compared with the T- and L-connected tapped winding capacitor motors.
  • Keywords
    capacitor motors; equivalent circuits; machine testing; machine windings; torque; 2-winding capacitor motors; L-connected tapped winding capacitor motors; T-connected tapped winding capacitor motors; alternating torque; efficiency; equivalent circuit parameters; optimum tap position; performance equations; shaft-mounted fans; steady-state torque speed curve; symmetrical components method; tapped auxiliary windings;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b:19870042
  • Filename
    4644406