• DocumentCode
    912795
  • Title

    Cage rotor heating at standstill

  • Author

    Williamson, S. ; Lloyd, M.R.

  • Author_Institution
    Imperial College, Department of Electrical Engineering, London, UK
  • Volume
    134
  • Issue
    6
  • fYear
    1987
  • fDate
    11/1/1987 12:00:00 AM
  • Firstpage
    325
  • Lastpage
    332
  • Abstract
    Induction motors classified as `increased safety¿ (Exe) must undergo a locked rotor test at full voltage, to determine the maximum cage temperature rise obtained within a specified time. The paper shows that the presence of stator MMF harmonics will cause the temperature rise observed during this test to vary from bar to bar around the rotor periphery. In a regular 3-phase machine the temperature will vary as the 6th harmonic of the fundamental pole number. In an irregular machine, such as a pole-change machine or a single-phase motor, the temperature distribution is more complex. It is shown that existing techniques of analysis can be used to give good estimates of the locked-rotor bar temperature distribution.
  • Keywords
    induction motors; machine testing; rotors; temperature distribution; induction motors; irregular machine; locked rotor test; locked-rotor bar temperature distribution; pole-change machine; regular 3-phase machine; rotor heating; single-phase motor; stator MMF harmonics;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b:19870049
  • Filename
    4644422