• DocumentCode
    922505
  • Title

    Elevation direction deconvolution in three-dimensional ultrasound imaging

  • Author

    Wang, Xinyu ; Ritchie, Cameron J. ; Kim, Yongmin

  • Author_Institution
    Center for Bioeng., Washington Univ., Seattle, WA, USA
  • Volume
    15
  • Issue
    3
  • fYear
    1996
  • fDate
    6/1/1996 12:00:00 AM
  • Firstpage
    389
  • Lastpage
    394
  • Abstract
    One-dimensional (1-D) linear transducer arrays can be used for three-dimensional (3-D) ultrasound image acquisition. However, the relatively low spatial resolution of these arrays in the elevation direction results in blurry 3-D images. Here, the authors introduce an elevation direction deconvolution (EDD) method that increases the spatial resolution of 3-D ultrasound images in the elevation direction. EDD is based on a deconvolution technique called power spectrum equalization. To evaluate the authors´ method, Cartesian volumes were reconstructed with and without EDD from a series of two-dimensional (2-D) images of phantoms. Using these reconstructed volumes, the authors first evaluated the effect of EDD on elevation resolution by computing the full-width-at-quarter-maximum (FWQM) of peaks along lines of constant depth. They then evaluated the effect of EDD on the accuracy of volume calculation by computing the phantom´s volumes. EDD decreased the FWQM of the peaks on elevation lines by an average of 17%; however, EDD did not significantly alter the accuracy of volume calculation. It is concluded that EDD can increase the spatial resolution in the elevation direction in 3-D ultrasound images and that EDD may improve the accuracy of volume calculation if a more consistent edge detection method is used
  • Keywords
    biomedical ultrasonics; deconvolution; image reconstruction; image resolution; image sequences; medical image processing; volume measurement; blurry 3D images; edge detection method; elevation direction deconvolution; full-width-at-quarter-maximum; low spatial resolution; medical diagnostic imaging; one-dimensional linear transducer arrays; peaks along constant depth lines; power spectrum equalization; reconstructed volumes; three-dimensional ultrasound image acquisition; three-dimensional ultrasound imaging; two-dimensional phantom images series; volume calculation accuracy; Accuracy; Deconvolution; Image edge detection; Image reconstruction; Imaging phantoms; Spatial resolution; Two dimensional displays; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.500148
  • Filename
    500148