• DocumentCode
    926375
  • Title

    Two-stage current transformers in differential calibration circuits

  • Author

    Betts, P.J.

  • Author_Institution
    Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Measurement Laboratory, Division of Applied Physics, Sydney, Australia
  • Volume
    130
  • Issue
    6
  • fYear
    1983
  • fDate
    1/1/1983 12:00:00 AM
  • Firstpage
    324
  • Lastpage
    328
  • Abstract
    The errors of a 2-stage current transformer (CT) are analysed when used as an isolated device or when used in a differential circuit. It is shown that when the CT is used in a differential circuit, or is operated at near zero external burden, a reduction in the errors of around two orders of magnitude can be gained. It is also shown that where the errors of a CT are largely a result of dielectric leakage, or of partial magnetic coupling, 2-staging will do little or nothing to reduce the errors.
  • Keywords
    calibration; current transformers; measurement errors; 2-stage current transformer; dielectric leakage; differential calibration circuits; isolated device; measurement errors; partial magnetic coupling;
  • fLanguage
    English
  • Journal_Title
    Physical Science, Measurement and Instrumentation, Management and Education - Reviews, IEE Proceedings A
  • Publisher
    iet
  • ISSN
    0143-702X
  • Type

    jour

  • DOI
    10.1049/ip-a-1.1983.0058
  • Filename
    4645864