  • Abstract
    It is shown that a typical network anlayser can be characterised in terms of three standards and five residual parameters, provided that all mismatches are invariant between the reflection and transmission modes of operation. The five residuals are expressed in terms of 22 internal parameters and the detector mismatches. Source mismatch does not contribute to systematic error, as is generally believed.
  • Keywords
    calibration; computer-aided circuit analysis; electronics applications of computers; error correction; network analysers; calibration equations; computer corrected network analyser; detector mismatches; internal parameters; reflection mode of operation; residual parameters; transmission modes of operation;