• DocumentCode
    940819
  • Title

    High magnetic field amplification for improving the sensitivity of Hall sensors

  • Author

    Leroy, Paul ; Coillot, Christophe ; Roux, Alain F. ; Chanteur, Gérard M.

  • Author_Institution
    Centre Nat. de la Recherche Scientifique, Velizy
  • Volume
    6
  • Issue
    3
  • fYear
    2006
  • fDate
    6/1/2006 12:00:00 AM
  • Firstpage
    707
  • Lastpage
    713
  • Abstract
    This paper describes the design of two magnetic concentrators that can be used to intensify the magnetic field in the active region of magnetic sensors, such as Hall sensors. The literature provides many examples of magnetic amplification, but magnetic gains never exceed 100 typically (Drljaca et al. 2001, Drljaca et al. 2002). We demonstrate that a larger magnetic field amplification (~1000 and even higher) can be achieved. Magnetic field amplification can even exceed the theoretical value fixed by the relative permeability of the material. Thus, the effective sensitivity of Hall sensors can be improved by at least three orders of magnitude by implementing them inside an especially tailored magnetic concentrator; noise-equivalent magnetic induction spectral density (National Electronics Manufacturing Initiative spectral density) down to 10 pT/radic(Hz) should be reached, using a good conditioning electronic
  • Keywords
    Hall effect transducers; magnetic fields; magnetic sensors; Hall sensors; magnetic concentrators; magnetic field amplification; magnetic induction spectral density; magnetic sensors; magnetometers; Magnetic field measurement; Magnetic fields; Magnetic flux; Magnetic noise; Magnetic sensors; Magnetosphere; Permeability; Saturation magnetization; Sensor phenomena and characterization; Signal to noise ratio; Hall sensors; magnetic amplification; magnetometers;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2006.874031
  • Filename
    1634424