• DocumentCode
    944126
  • Title

    Coupling time constants for modified jelly roll Nb/sub 3/Sn wires

  • Author

    McKinnell, J.C. ; Siddall, M.B. ; Smathers, D.B.

  • Author_Institution
    Teledyne Wah Chang Albany, OR, USA
  • Volume
    3
  • Issue
    1
  • fYear
    1993
  • fDate
    3/1/1993 12:00:00 AM
  • Firstpage
    472
  • Lastpage
    475
  • Abstract
    Measurement of the coupling time constant allows an estimate of the coupling loss in AC applications. The authors report the coupling time constants of modified jelly-roll niobium-tin (Nb/sub 3/Sn) wires which were measured using a modified version of the technique described by T. Ando et al. (1985, 1988). The coupling time constant is reported for over 200 km of wire at zero applied field. If the pulse field was large enough, two characteristic time constants were observed at zero field. The longer of the two time constants was not observed when a DC magnetic field of >or=0.1 T was applied to the sample. The field behavior of the coupling time constant from 0 to 6 T is also reported.<>
  • Keywords
    fusion reactor materials; niobium compounds; superconducting cables; superconducting magnets; 0 to 6 T; 200 km; AC applications; DC magnetic field; Nb/sub 3/Sn; coupling loss; coupling time constant; modified jelly roll Nb/sub 3/Sn wires; pulse field; Atmospheric measurements; Couplings; Fasteners; Magnetic field measurement; Niobium; Superconducting coils; Tin; Voltage; Wire; Wounds;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.233746
  • Filename