• DocumentCode
    948130
  • Title

    Optimal Source Distribution for Hyperthermia at the Center of a Sphere of Muscle Tissue

  • Author

    Rappaport, Carey M. ; Morgenthaler, Frederic R.

  • Volume
    35
  • Issue
    12
  • fYear
    1987
  • fDate
    12/1/1987 12:00:00 AM
  • Firstpage
    1322
  • Lastpage
    1327
  • Abstract
    In noninvasive electromagnetic hyperthermia it is important that applicators deposit as least as much power at the tumor as anywhere else in the intervening tissue. This study determines the ideal penetration limits for heating the center of a volume of muscle tissue according to this constraint. First, it is shown that the most efficiently heated volume is a sphere. Then, using both a diffraction integral formulation and a spherical harmonic modal approach, field distributions within the sphere are derived. It is shown that combining odd harmonics can generate a nearly uniform surface power distribution, and that this distribution is optimal. The power deposition patterns for these distributions for various standard frequencies are presented. It is concluded that 915 MHz is the best frequency for heating spheres less than 9.5 cm in radius.
  • Keywords
    Applicators; Cogeneration; Diffraction; Frequency; Hyperthermia; Muscles; Neoplasms; Power distribution; Power generation; Power system harmonics;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1987.1133855
  • Filename
    1133855