DocumentCode
949430
Title
Motor temperature considerations for pulp and paper mill applications
Author
Albers, Timothy ; Bonnett, Austin H.
Author_Institution
U.S. Electrical Motors/Emerson Motor Company, St. Louis, MO, USA
Volume
38
Issue
6
fYear
2002
Firstpage
1701
Lastpage
1713
Abstract
This paper reviews the motor temperature operating consideration for totally enclosed fan cooled (TEFC), open dripproof and weather protected II type of motor through 500 hp, both low voltage (LV) and medium voltage (MV). The IEEE Standard 841 has been revised as IEEE Std 841-2001 and is expected to be in use for at least five years. The TEFC motors covered in this standard have found wide acceptance in the pulp and paper industry. Much of the material also applies to large motors sizes. The thermal impact on the stator winding rotor core, bearings, and lubrications as specified in standards and applied in mills are considered.
Keywords
IEEE standards; cooling; machine bearings; packaging; paper industry; rotors; squirrel cage motors; stators; temperature distribution; thermal analysis; 500 hp; AC squirrel-cage induction motors; IEEE Standard 841; IEEE Std 841-2001; Weather Protected II type motor; bearings; large motors sizes; lubrications; motor temperature considerations; open dripproof motor; paper mill; pulp mill; stator winding rotor core; totally enclosed fan cooled motor; Low voltage; Medium voltage; Milling machines; Paper mills; Protection; Pulp and paper industry; Rotors; Stator cores; Stator windings; Temperature;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2002.805574
Filename
1058128
Link To Document