• DocumentCode
    952523
  • Title

    Simplified fext calculations

  • Author

    McLachlan, R.V.

  • Author_Institution
    Post Office Research Centre, Ipswich, UK
  • Volume
    15
  • Issue
    18
  • fYear
    1979
  • Firstpage
    545
  • Abstract
    The minimum value of far-end crosstalk attenuation (FEXTA) occurs for a disturbing-pair loss of 1 Neper with uncorrelated coupling and 0.5 Neper with correlated coupling. This information can greatly simplify assessing the far-end crosstalk performance of telemetry and similar transmission systems.
  • Keywords
    crosstalk; telemetering; disturbed pair loss; far end crosstalk attenuation; telemetry; transmission systems;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19790391
  • Filename
    4243513