DocumentCode
956368
Title
Frequency deviation measurement based on two-arm Δ-Σ modulated bridge
Author
Zrilic, Djuro G. ; Pjevalica, Nebojsa U.
Author_Institution
Dept. of Eng., New Mexico Highlands Univ., Las Vegas, NM, USA
Volume
53
Issue
2
fYear
2004
fDate
4/1/2004 12:00:00 AM
Firstpage
293
Lastpage
299
Abstract
A method of frequency deviation measurement is presented. The use of a two-arm bridge is based on the use of delta-sigma (Δ-Σ) modulation and arithmetic operations on two synchronous Δ-Σ modulated pulse streams. The simulation results indicate a good linear relationship between frequency deviation and pulse count over the operating range. Stability of the clock and components mismatch of the Δ-Σ modulator are not critical for operation. Performance comparisons with existing solutions are given.
Keywords
frequency measurement; sigma-delta modulation; arithmetic operations; clock stability; component stability; delta-sigma modulation; delta-sigma modulator; delta-sigma pulse stream; frequency deviation measurement; pulse count; synchronous delta-sigma modulated pulse streams; two-arm bridge; Bridge circuits; Counting circuits; Delta modulation; Detectors; Frequency measurement; Power engineering and energy; Power system measurements; Pulse measurements; Pulse modulation; Pulse power systems;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2003.822709
Filename
1284858
Link To Document