• DocumentCode
    956368
  • Title

    Frequency deviation measurement based on two-arm Δ-Σ modulated bridge

  • Author

    Zrilic, Djuro G. ; Pjevalica, Nebojsa U.

  • Author_Institution
    Dept. of Eng., New Mexico Highlands Univ., Las Vegas, NM, USA
  • Volume
    53
  • Issue
    2
  • fYear
    2004
  • fDate
    4/1/2004 12:00:00 AM
  • Firstpage
    293
  • Lastpage
    299
  • Abstract
    A method of frequency deviation measurement is presented. The use of a two-arm bridge is based on the use of delta-sigma (Δ-Σ) modulation and arithmetic operations on two synchronous Δ-Σ modulated pulse streams. The simulation results indicate a good linear relationship between frequency deviation and pulse count over the operating range. Stability of the clock and components mismatch of the Δ-Σ modulator are not critical for operation. Performance comparisons with existing solutions are given.
  • Keywords
    frequency measurement; sigma-delta modulation; arithmetic operations; clock stability; component stability; delta-sigma modulation; delta-sigma modulator; delta-sigma pulse stream; frequency deviation measurement; pulse count; synchronous delta-sigma modulated pulse streams; two-arm bridge; Bridge circuits; Counting circuits; Delta modulation; Detectors; Frequency measurement; Power engineering and energy; Power system measurements; Pulse measurements; Pulse modulation; Pulse power systems;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2003.822709
  • Filename
    1284858