• DocumentCode
    982397
  • Title

    Properties of an 8 T pulse magnet

  • Author

    Irie, F. ; Takeo, M. ; Sumiyoshi, F. ; Tahara, S.

  • Author_Institution
    Kyushu University, Fukuoka, Japan
  • Volume
    17
  • Issue
    5
  • fYear
    1981
  • fDate
    9/1/1981 12:00:00 AM
  • Firstpage
    1962
  • Lastpage
    1965
  • Abstract
    Pulse losses and instability for an 8 T pulse magnet is investigated experimentally whose developement has already been reported. Measured loss is separated into two parts, i.e. hysteresis loss and eddy current loss. Hysteresis losses agree fairly well with theoretical values which take account of the decrease of the critical current near Bc2. It is confirmed from the results of analysis that eddy current losses are generated mainly from the outer copper sheath of cable. Next, stability is tested in the rather heavy duty cycle operation with high ramp-rates. No sign of instability or change is observed during repeated pulse cycles.
  • Keywords
    Superconducting magnets; Cable shielding; Copper; Critical current; Current measurement; Eddy currents; Hysteresis; Loss measurement; Magnetic losses; Magnetic properties; Magnetic separation;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1981.1061308
  • Filename
    1061308