• DocumentCode
    993185
  • Title

    CMOS detector readout electronics for an emission-transmission medical imaging system

  • Author

    Heanue, J.A. ; Boser, B.E. ; Hasegawa, B.H.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., California Univ., Berkeley, CA, USA
  • Volume
    42
  • Issue
    4
  • fYear
    1995
  • fDate
    8/1/1995 12:00:00 AM
  • Firstpage
    1133
  • Lastpage
    1138
  • Abstract
    We have built a prototype medical imaging system in which transmission X-ray data provide anatomical information while emission radionuclide data yield physiological information. We have developed a CMOS integrated circuit for readout of the system´s high-purity germanium detector. The circuit can be operated in three different modes. The first is a slow pulse-counting mode for detection of radionuclide events at 104 cps with 1-2 keV energy resolution. Next, there is a fast pulse-counting mode for simultaneous acquisition of emission and transmission data or for acquisition of dual-energy X-ray data at 106 cps with 5-7 keV energy resolution. Finally, current mode operation allows fast acquisition of X-ray transmission data. The circuit architecture includes a common preamplifier, selectable pulse shaping stages, and a common output buffer
  • Keywords
    CMOS integrated circuits; counting circuits; data acquisition; emission tomography; germanium radiation detectors; nuclear electronics; preamplifiers; pulse shaping circuits; single photon emission computed tomography; CMOS detector readout electronics; CMOS integrated circuit; Ge; HPGe detector; SPECT; X-ray computed tomography; anatomical information; common preamplifier; current mode operation; dual-energy X-ray data; emission radionuclide data; emission-transmission computed tomography; emission-transmission medical imaging system; fast pulse-counting mode; high-purity Ge detector; physiological information; prototype medical imaging system; selectable pulse shaping stages; simultaneous acquisition; single photon emission computed tomography; slow pulse-counting mode; transmission X-ray data; transmission data; Biomedical imaging; CMOS integrated circuits; Detectors; Energy resolution; Event detection; Germanium; Integrated circuit yield; Prototypes; Readout electronics; X-ray imaging;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.467736
  • Filename
    467736