• شماره ركورد
    442040
  • عنوان مقاله

    بررسي ميزان دقت راديو گرافي ديجيتال تفريقي در تشخيص تحليل خارجي مصنوعي ريشه در شرايط آزمايشگاهي

  • عنوان به زبان ديگر
    Accuracy of digital subtraction radiography in detection of artificial external root resorption (in vitro)
  • پديد آورندگان

    -، - گردآورنده - Ghafari , R

  • اطلاعات موجودي
    فصلنامه سال 1387 شماره 0
  • رتبه نشريه
    علمي پژوهشي
  • تعداد صفحه
    8
  • از صفحه
    141
  • تا صفحه
    148
  • كليدواژه
    راديوگرافي ديجيتال تفريقي , راديوگرافي ديجيتال مستقيم , تحليل خارجي ريشه
  • چكيده لاتين
    Introduction; External root resorption refers to the loss of cementum and/or dentin from the root of the teeth. 40% mineral loss occur in conventional radiographics but digital subtraction radiography is capable of localizing a lesion with only 1-5% mineral loss. This in vitro study aimed to determine the accuracy of digital subtraction radiography in diagnosis of simulated external root resorption.Methods and Materials: Ten premolar teeth with clinically intact roots were used were fixed in suitable place between the X-ray tube and CCD sensor. Direct digital radiographs were obtained before and after each lesion was created by 1/2, 1, 2, 4 and 6 round dental burs at facial and proximal surfaces; then digital subtraction images were obtained and observers evaluated all of the images and sensitivity and specificity and accuracy were calculated. Results were compared by % test (a = 0.05).Results: The sensitivity of digital subtraction and direct digital methods in detecting proximal defects were 97.34%) and 93.92% respectively (p value = 0.16). The sensitivity of digital subtraction and direct digital radiography in facial surfaces were 98% and 92.6%) respectively (p value = 0.03). The specificity of direct digital and subtraction methods in proximal surfaces were 91.92%o and 96.52% (p value = 0.08) and in facial surfaces were 91.92%) and 99.26%o respectively (p value = 0.002). The accuracy of digital subtraction radiography in detecting facial lesion was significantly superior to direct digital radiography.Conclusion: Digital subtraction radiography was superior to direct digital radiography in detecting small external root resorptive defects.
  • سال انتشار
    1387
  • عنوان نشريه
    م‍ج‍ل‍ه‌ دان‍ش‍ك‍ده‌ دن‍دان‍پ‍زش‍ك‍ي‌ اص‍ف‍ه‍ان‌
  • عنوان نشريه
    م‍ج‍ل‍ه‌ دان‍ش‍ك‍ده‌ دن‍دان‍پ‍زش‍ك‍ي‌ اص‍ف‍ه‍ان‌
  • اطلاعات موجودي
    فصلنامه با شماره پیاپی 0 سال 1387
  • كلمات كليدي
    #تست#آزمون###امتحان