شماره ركورد
524781
عنوان مقاله
بررسي مقايسه اي دقت Cone beam CT، راديوگرافي داخل دهاني و پروب پريودنتال در اندازه گيري ضايعات استخواني پريودنتال
عنوان به زبان ديگر
Accuracy of cone beam computed tomography, intraoral radiography and periodontal probing
for periodontal bone defects measurement
پديد آورندگان
دهقاني ، مهديه نويسنده dehghani, mahdie , بردال، رقيه نويسنده دانشكده دندانپزشكي-دانشگاه علوم پزشكي همدان Bardal , roghayeh , اسكندرلو، امير 1339 نويسنده پزشكي Eskandarlo, amir
اطلاعات موجودي
فصلنامه سال 1390 شماره 66
رتبه نشريه
علمي پژوهشي
تعداد صفحه
5
از صفحه
15
تا صفحه
19
كليدواژه
Cone beam computed tomography , داخل دهاني , پروب
چكيده لاتين
Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.
Materials and Methods: Two-hundred and eighteen artificial osseous defects (buccal and lingual infrabony, interproximal, horizontal, crater, dehiscence and fenestration defects) were created on 13 mandibles of dry skulls. The mandibles were put into a plexiglass box full of water to simulate soft tissue. CBCT images, radiographic images taken with parallel technique and direct measurements using a WHO periodontal probe were recorded and compared to a standard reference (digital caliper). Inter and intra observe consistencies were assessed using Intra class correlation coefficient and pearson correlation.
Results: Inter and intra observer consistencies were high for CBCT and probing methods (ICC- Intra class correlation coefficient >88%), but moderate for intraoral radiography (ICC-Intra class correlation coefficient > 54%). There were not any significant differences between observers for all techniques (P>0/05). According to paired T-test analysis, mean difference for CBCT technique (0.01 mm) was lower than that for probing (0.04 mm) and radiography (0.62 mm). CBCT was able to measure all kinds of lesions, but radiography could not measure defects in the buccal and lingual sites.
Conclusion: All three modalities are useful for identifying periodontal defects. Compared to probing and radiography, the CBCT technique has the most accuracy in measuring periodontal defects
سال انتشار
1390
عنوان نشريه
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي
فصلنامه با شماره پیاپی 66 سال 1390
كلمات كليدي
#تست#آزمون###امتحان
لينک به اين مدرک