Title of article :
Design parameters for measurements of local
catalytic activity on surfaces
Author/Authors :
M. Johansson، نويسنده , , T. Johannessen، نويسنده , , J. Hoffmann J?rgensen، نويسنده , , Ib Chorkendorff، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Computational fluid dynamics in combination with experiments is used to characterize a gas sampling device for
measurements of the local catalytic activity on surfaces. The device basically consists of a quartz capillary mounted
concentrically inside an aluminum tube. Reactant gas is blown toward the catalytic surface through the annulus between
the tubes, and the gas is sampled close to the surface by the capillary. The influence of various design parameters on the lateral
resolution and sensitivity of the measurements is investigated. It is found that the outer diameter of the annulus sets the upper
limit for the lateral resolution of the measurement, and that a flow rate of the order of 240 (ml/min)n is sufficient to achieve this
resolution. The sensitivity is reasonable also with high flow rates, due to the presence of a pocket of stagnant gas under the tip of
the capillary. Furthermore, the limits of the range in reaction rate, which can be studied are estimated.
Keywords :
Local gas sampling , Local reaction rate , Heterogeneous catalysis
Journal title :
Applied Surface Science
Journal title :