Title of article :
Time delay for arrival of MR contrast agent in collateral-dependent myocardium
Author/Authors :
M.، Jerosch-Herold, نويسنده , , Hu، Xudong نويسنده , , N.S.، Murthy, نويسنده , , R.T.، Seethamraju, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
-880
From page :
881
To page :
0
Abstract :
An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, gives a direct estimate of myocardial blood flow. In this paper, we analyze the effects of delays in the contrast enhancement, that occur in collateral-dependent myocardium, where the tracer reaches the tissue region only through branches from other coronary arteries that form natural bypass vessels. We investigate how the delayed arrival of tracer alters the myocardial impulse response. Model-independent deconvolution is applied to determine the lag between arterial input and tissue enhancement. Experimental data in a porcine model of collateral development indicate that the delayed arrival of an injected tracer, measured at rest, is a useful marker to identify collateral-dependent myocardium, and predict its flow capacitance.
Keywords :
Hydrograph
Journal title :
IEEE Transactions on Medical Imaging
Serial Year :
2004
Journal title :
IEEE Transactions on Medical Imaging
Record number :
100890
Link To Document :
بازگشت