• Title of article

    Linear structures in mammographic images: detection and classification

  • Author/Authors

    R.، Zwiggelaar, نويسنده , , S.M.، Astley, نويسنده , , C.R.M.، Boggis, نويسنده , , C.J.، Taylor, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    -1076
  • From page
    1077
  • To page
    0
  • Abstract
    We describe methods for detecting linear structures in mammograms, and for classifying them into anatomical types (vessels, spicules, ducts, etc). Several different detection methods are compared, using realistic synthetic images and receiver operating characteristic (ROC) analysis. There are significant differences (p<0.001) between the methods, with the best giving an A/sub z/ value for pixel-level detection of 0.943. We also investigate methods for classifying the detected linear structures into anatomical types, using their cross-sectional profiles, with particular emphasis on recognising the "spicules" and "ducts" associated with some of the more subtle abnormalities. Automatic classification results are compared with expert annotations using ROC analysis, demonstrating useful discrimination between anatomical classes (A/sub z/=0.746). Some of this discrimination relies on simple attributes such as profile width and contrast, but important information is also carried by the shape of the profile (A/sub z/=0.653). The methods presented have potentially wide application in improving the specificity of abnormality detection by exploiting additional anatomical information.
  • Keywords
    Hydrograph
  • Journal title
    IEEE Transactions on Medical Imaging
  • Serial Year
    2004
  • Journal title
    IEEE Transactions on Medical Imaging
  • Record number