• Title of article

    Compositional analysis of ferroelectric films coated with carbon layer using laser-induced plasmas spectroscopy

  • Author/Authors

    Q.L. Zhang، نويسنده , , J.P. Zhang، نويسنده , , C.Y. Liang، نويسنده , , B.T. Li، نويسنده , , X. Li، نويسنده , , Q.L. Guo، نويسنده , , G.S. Fu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    3
  • From page
    7669
  • To page
    7671
  • Abstract
    An experimental investigation of the effect of different thickness of carbon layer coated on ferroelectric films on the atomic emission intensity using laser-induced plasmas spectroscopy technique with charge-coupled device (CCD) experimental system has been conducted. The experimental results show that the intensity of the spectra emitted with the carbon layer thickness of 15 μm is much higher than that of pure ferroelectric films. By using this best experimental condition, the atomic concentration ratios of ferroelectric films are evaluated by rationing the integrated intensities of selected spectral emission lines of the plasma produced from the films. And the experimental results show that NLa/NCo and NSr/NCo atomic concentration ratios are almost in agreement with the corresponding values obtained by traditional compositional analysis techniques of inductively coupled plasma (ICP).
  • Keywords
    Carbon , Laser-induced plasmas spectroscopy , Signal enhancement
  • Journal title
    Applied Surface Science
  • Serial Year
    2009
  • Journal title
    Applied Surface Science
  • Record number