Title of article :
Constant-load delayed fracture test of atmospherically corroded high strength steels
Author/Authors :
Eiji Akiyama، نويسنده , , Katsuhiro Matsukado، نويسنده , , Songjie Li، نويسنده , , Takahito Ohmura Kaneaki Tsuzaki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
8275
To page :
8281
Abstract :
Constant load tests of circumferentially notched round bar specimens of high strength steels after cyclic corrosion test and outdoor exposure have been performed to demonstrate that delayed fracture occurs when the hydrogen content from the environment, HE, exceeds the critical hydrogen content for delayed fracture, HC. During the constant load tests the humidity around the specimen was increased in stepwise manner to increase hydrogen entry. After fracture the specimen was kept at the humidity long enough to homogenize hydrogen in the specimen and to obtain more quantitative hydrogen content by thermal desorption analysis. HE of the fractured specimens was higher than HC, and HE of the specimens not fractured was lower than HC. This result confirms that the balance between HC and HE determines the occurrence of delayed fracture and that hydrogen-content-based evaluation of susceptibility to delayed fracture is reasonable. To certify the increase of HE with increase in humidity, electrochemical hydrogen permeation test was carried out. The hydrogen permeation current density was increased especially at 98%RH. Enhancement of hydrogen entry with increase in CCT number was also shown by the test.
Keywords :
Hydrogen embrittlement , Atmospheric corrosion , High strength steel , Delayed fracture
Journal title :
Applied Surface Science
Serial Year :
2011
Journal title :
Applied Surface Science
Record number :
1014709
Link To Document :
بازگشت