• Title of article

    Enhancement of peroxyoxalate chemiluminescence by copper(II) in flow injection analysis; optimization by factorial design analysis

  • Author/Authors

    O.M. Steijger، نويسنده , , H.C.M. Den Nieuwenboer، نويسنده , , H. Lingeman، نويسنده , , Udo A.Th. Brinkman، نويسنده , , J.J.M. Holthuis، نويسنده , , A.K. Smilde، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    7
  • From page
    99
  • To page
    105
  • Abstract
    A flow injection analysis (FIA) system with peroxyoxalate chemiluminescence (CL) detection was optimized by factorial design analysis in the absence and presence of Cu(II) ions. The carrier stream was a mixture of acetonitrile and an aqueous imidazole solution of pH 7.O. The effect of the metal ions was determined by adding Cu(II) nitrate to the imidazole solution. A mixture of 5 mM bis(2-nitrophenyl)oxalate solution in acetonitrile and hydrogen peroxide was used as reagent solution. The fluorophore used was 3-aminofluoranthene dissolved in acetonitrile to a concentration of 12.5 nM. The parameters of the factorial design experiment in the absence of Cu(II), were the concentration of hydrogen peroxide and imidazole, the percentage of acetonitrile and the length of the mixing coil; those of experiments in the presence of the metal ions, the concentration of imidazole and Cu(II) and the length of the mixing coil. The enhancement of the chemiluminescence intensity by Cu(II) in the FIA system was found to be 70%.
  • Keywords
    Flow injection , Peroxyoxalate chemiluminescence , Chemiluminescence , Copper: Factorial design analysis
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    1996
  • Journal title
    Analytica Chimica Acta
  • Record number

    1022999