Title of article :
Use of two-phase loop thermosyphons for thermoelectric refrigeration: experiment and analysis
Author/Authors :
J.S. Lee ، نويسنده , , S.H. Rhi، نويسنده , , C.N. Kim، نويسنده , , Y. Lee، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
10
From page :
1167
To page :
1176
Abstract :
Reported are the results of an experimental and analytical (simulation) study on a thermoelectric refrigeration system employing two two-phase loop thermosyphons. The experimental results show that a heat transfer rates of up to about 29 W/°C m2 (the area based on the outside heat transfer area of the condenser sections) or about 5400 W/°C m2 (the area based on the heat transfer area of the Peltier element) at the average air temperature of the refrigerator of −4.6 °C, with an ambient outside air temperature of 25 °C, can be attainable under the forced convection heat transfer at the finned evaporator and condenser sections.
Keywords :
Thermoelectric refrigeration , Two-phase loop thermosyphon , simulation , Peltier element
Journal title :
Applied Thermal Engineering
Serial Year :
2003
Journal title :
Applied Thermal Engineering
Record number :
1023773
Link To Document :
بازگشت