Title of article :
Flow injection chemiluminescence determination of hydrazine
Author/Authors :
A Safavi، نويسنده , , M.R Baezzat، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Abstract :
A sensitive and selective flow injection chemiluminescence method for the determination of hydrazine over the range 1×10−6−5×10−5 M is described. The method is based on the chemiluminescence emitted during the oxidation of hydrazine by N-bromosuccinimide in alkaline medium in the presence of dichlorofluorescein as sensitizer. The presence of citrate prevents the precipitation of some cations in the reaction medium and also causes an enhancement in chemiluminescence intensity. Method development includes optimization of reagent concentrations and flow conditions. The optimized method yielded a 2σ detection limit of 5×10−7 M. The method also has good selectivity. The method is simple, fast, selective and precise.
Keywords :
Flow injection , Hydrazine , Chemiluminescence
Journal title :
Analytica Chimica Acta
Journal title :
Analytica Chimica Acta